湖北农业科学 ›› 2020, Vol. 59 ›› Issue (20): 71-74.doi: 10.14088/j.cnki.issn0439-8114.2020.20.015

• 资源环境 • 上一篇    下一篇

基于ADTD的城市与平原不同下垫面状况对闪电特征影响的分析

李政, 范旻琪, 赵涛, 王小飞   

  1. 湖北省防雷中心,武汉 430074
  • 收稿日期:2020-05-25 出版日期:2020-10-25 发布日期:2020-12-04
  • 作者简介:李政(1984-),男,江苏沭阳人,副高级工程师,硕士,主要从事雷电防护技术和雷电风险评估方法的研究,(电话)027-67848265(电子信箱)45078168@qq.com。
  • 基金资助:
    湖北省雷电灾害防御科研专项(FL-Z-201402)

Analysis of the influence of different underlying surface conditions on lightning characteristics in cities and plains based on ADTD

LI Zheng, FAN Min-qi, ZHAO Tao, WANG Xiao-fei   

  1. Lightning Protection Center of Hubei Province,Wuhan 430074,China
  • Received:2020-05-25 Online:2020-10-25 Published:2020-12-04

摘要: 利用湖北省ADTD闪电定位系统记录的江汉平原天门市、仙桃市、潜江市城市下垫面与3个城市外围平原下垫面的地闪数据,通过对地闪数据中闪电频次、闪电极性、闪电幅值、累积概率等闪电特征进行归纳分析对比,从而揭示湖北省内在同一大气环流背景下城市与平原2种不同下垫面状况对闪电具体特征的影响。结果表明,在同一大气环流背景下,城市与平原下垫面之间同时发生闪电的相关系数较高,因为下垫面特征产生的局部闪电比例较低;城市下垫面对应的正闪电比例高于平原下垫面,但是其正闪平均幅值较低,呈负相关;城市下垫面的闪电幅值分布更加集中,主要在20~35 kA;城市下垫面与平原下垫面相比,雷电流平均幅值大0.91 kA,雷电流累积概率中值电流大0.90 kA,60.0 kA以上的雷电流也表现为城市下垫面更多。

关键词: ADTD, 下垫面, 闪电特征, 湖北省

Abstract: Using the lightning data in Hubei province meteorological department layout ADTD system to record the lightning location system laying,the difference of the surface features of lightning in the Jianghan Plain,Tianmen,Xiantao,Qianjiang three cities underlying surface and near the suburban plain are analyzed,in order to explain the influence of city and plain under different surface conditions on the characteristics of lightning.The results show thatIn the same atmospheric circulation background,the correlation coefficient of simultaneous lightning between urban and plain underlying surface is higher,because the proportion of local lightning generated by underlying surface characteristics is lower;The proportion of positive lightning of city underlying surface is higher than that of flash plain surface,but the average amplitude of positive lightning is low,inversely related;City underlying surface lightning amplitude distribution is more concentrated,mainly in 20~35 kA;Compared with the plain underlying surface,the average amplitude of lightning current is 0.91 kA higher,the median cumulative probability of lightning current is 0.90 kA higher,and the urban underlying surface of lightning current over 60.0 kA is also more.

Key words: ADTD, underlying surface, lightning characteristics, Hubei province

中图分类号: